Main technical index
Functions and parameters
Leakage detection accuracy 1.0E-7~1.0E-4Pa.m3/s
Helium filling pressure
designed according to the demand side's requirements
Detection rhythm 1min~5min/piece
Detection method
Check the overall leakage rate, and can also assist in using the suction gun method to find leakage points
Level 3 leakage detection
major leakage detection, medium leakage detection, and minor leakage detection
Structural style
bell type/sliding door type/side door type, etc
Security protection grating protection, electrical interlocking, hierarchical password, sound and light alarm
Economy
Helium recovery and recycling, low maintenance cos
Automation
PLC control, touch screen operation, automatic evacuation, detection, and helium recovery
Intelligent
remote monitoring, automatic storage of data, communication with MES or databases