-
Pressure sensor industry
Leakage detection accuracy 1.0E-6~1.0E-5Pa.m3/s; Helium filling pressure 1.5~7.0MPa; Detection rhythm 7s~15s/piece; Detection method Check the overall leakage rate; Multi level leak detection detecting major and minor leaks Level 3 leakage detection major leakage detection, medium leakage detection, and minor leakage detection; Structural style bell type Security protection grating protection, electrical interlocking, hi...
Learn More
> -
Corrugated Pipe industry
Leakage detection accuracy 1.0E-6~1.0E-5Pa.m3/s; Helium filling pressure 0.05~0.3MPa; Detection rhythm 10min~20min/reel; Detection method Check the overall leakage rate; Level 3 leakage detection major leakage detection, medium leakage detection, and minor leakage detection; Structural style side door opening, etc Security protection grating protection, electrical interlocking, hierarchical password, sound and light alarm; E...
Learn More
> -
Fire extinguisher industry
Leakage detection accuracy 1.0E-7~1.0E-4Pa.m3/s; Helium filling pressure 1.0~3.0MPa; Detection rhythm 0.5min~3min/piece; Detection method Check the overall leakage rate, and can also assist in using the suction gun method to find leakage points; Level 3 leakage detection major leakage detection, medium leakage detection, and minor leakage detection; Structural style bell type/sliding door type/side door type, etc Security protection gr...
Learn More
> -
Hydrogen cylinder industry
Leakage detection accuracy 6NmL/(h·L), 1.0E-6~1.0E-3Pa.m3/s; Helium filling pressure 35.0~87.5MPa; Detection rhythm hydrogen cylinder: 15-60min/piece; Detection method Check the overall leakage rate, and can also assist in using the suction gun method to find leakage points; Structural style side door opening; Security protection grating protection, electrical interlocking, hierarchical password, sound and light alarm; Automation PLC c...
Learn More
> -
Water cooled panels industry
Leakage detection accuracy 1.0E-7~1.0E-4Pa.m3/s; Helium filling pressure 0.25~2.0MPa; Detection rhythm 20s~300s/piece; Detection method Check the overall leakage rate, and can also assist in using the suction gun method to find leakage points; Level 3 leakage detection major leakage detection, medium leakage detection, and minor leakage detection; Structural style bell type/sliding door type etc; Security protection grating protection, ...
Learn More
> -
High voltage GIS industry
Leakage detection accuracy SF6/NON-SF6 gas, 0.01%~0.5%/year Helium filling pressure 0~0.8MPa; Detection rhythm 10min~60min/piece; Detection method positive pressure suction method, manually holding a helium suction gun to detect leaks at the leakage point; Configuration selection helium recovery system+helium mass spectrometer leak detector; Security protection electrical interlocking, hierarchical password, sound and light alarm; Econo...
Learn More
> -
Power GIS switchgear industry
Leakage detection accuracy: SF6/NON-SF6 gas, 0.01%~0.5%/year; Helium filling pressure: 0~0.05MPa; Filling pressure of SF6/NON-SF6 0.1~0.15MPa; Detection rhythm: 15min~60min/piece; Detection method: Check the overall leakage rate and also assist in finding leakage points; Level 3 leakage detection: major leakage detection, medium leakage detection, and minor leakage detection; Structural style: automatic side door opening type; Security protection: grati...
Learn More
> -
Compressor industry
Leakage detection accuracy: refrigerant 1g/y~14g/y, i.e.5.0E-7~7.0E-6Pa.m3/s; Helium filling pressure: 0~2.5MPa; Detection rhythm: 30s~180s/piece; Detection method: Check the overall leakage rate and also assist in finding leakage points; Level 3 leakage detection: major leakage detection, medium leakage detection, and minor leakage detection; Structural style: Bell type/sliding door type; Security protection: grating protection, action interlocking, hierarchical passwo...
Learn More
> -
Condenser/Evaporator/Radiator industry
Leakage detection accuracy: refrigerant 1g/y~10g/y, i.e.5.0E-7~5.0E-6Pa.m3/s; Helium filling pressure: 0~3.0MPa; Detection rhythm: 30s~60s/piece; Detection method: Check the overall leakage rate and also assist in finding leakage points; Level 3 leakage detection: major leakage detection, medium leakage detection, and minor leakage detection; Structural style: duck billed/flip over/inclined sliding door; Security protection: grating protection, action interlocking, hierarchical pas...
Learn More
>