Water cooled panels helium leak detection system
Vacuum chamber helium leak detection and recovery system >Application
Mainly used for leak detection of water-cooled workpieces, such as PACK, water-cooled plates, liquid cooled plates, oil coolers, water channels, and other products.
-
Main technical index
Functions and parameters
Leakage detection accuracy 1.0E-7~1.0E-4Pa.m3/s
Detection rhythm
20s~300s/piece
Helium filling pressure
0.25~2.0MPa
Detection method Check the overall leakage rate, and can also assist in using the suction gun method to find leakage points
Level 3 leakage detection
major leakage detection, medium leakage detection, and minor leakage detection
Structural style
bell type/sliding door type etc;
Security protection
grating protection, electrical interlocking, hierarchical password, sound and light alarm
Economy
Helium recovery and recycling, low maintenance cost
Automation PLC control, touch screen operation, automatic evacuation, detection, and helium recovery
Intelligent
remote monitoring, automatic storage of data, communication with MES or databases
Applicability
Non standard customized solutions to meet customer needs